Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts

Cover Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts
Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts
Cambridge Mass. Building Law Commission
The book Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts was written by author Here you can read free online of Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts book, rate and share your impressions in comments. If you don't know what to write, just answer the question: Why is Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts a good or bad book?
Where can I read Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts for free?
In our eReader you can find the full English version of the book. Read Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts Online - link to read the book on full screen. Our eReader also allows you to upload and read Pdf, Txt, ePub and fb2 books. In the Mini eReder on the page below you can quickly view all pages of the book - Read Book Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts
What reading level is Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts book?
To quickly assess the difficulty of the text, read a short excerpt:


Piers and Hearths.
1 Section 30. Piers and walls shall have caps or 2 plates of iron or stone where they are needed, sufficient 3 properly to distribute the load.
4 Hearths shall be supported by trimmer arches of 5 brick or stone; or shall be of single stcmes at least six 6 inches thick, built into the chimney and supported by iron 7 beams, one end of which shall be securely built into the 8 masonry of a chimney or of an adjoining wall, or which 9 shall otherwise rest upon an incombustible supp
...ort.
10 Rough brick jambs of every fireplace, range or grate 1 1 opening shall each be at least eight inches wide, and the 1 2 backs of such openings shall be at least eight inches thick.
13 Hearths and trimmer arches shall be at least twelve 14 inches longer on either side than the width of such open- 15 ings, and at least eighteen inches wide in front of the 16 chimney breast. Brickwork over fireplaces and grate 17 openings shall be supported by proper iron bars, or brick 18 or stone arches.
Walls — Doorways in Party Walls.


What to read after Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts?
You can find similar books in the "Read Also" column, or choose other free books by Cambridge Mass. Building Law Commission to read online
MoreLess

Read book Proposed Draft of a Building Ordinance for the City of Cambridge, Massachusetts for free

Ads Skip 5 sec Skip
+Write review

User Reviews:

Write Review:

Guest

Guest