Re-Design of the Transmission System of the Edison Electric Company of Southern California

Cover Re-Design of the Transmission System of the Edison Electric Company of Southern California
Re-Design of the Transmission System of the Edison Electric Company of Southern California
Frank K Brainard
The book Re-Design of the Transmission System of the Edison Electric Company of Southern California was written by author Here you can read free online of Re-Design of the Transmission System of the Edison Electric Company of Southern California book, rate and share your impressions in comments. If you don't know what to write, just answer the question: Why is Re-Design of the Transmission System of the Edison Electric Company of Southern California a good or bad book?
Where can I read Re-Design of the Transmission System of the Edison Electric Company of Southern California for free?
In our eReader you can find the full English version of the book. Read Re-Design of the Transmission System of the Edison Electric Company of Southern California Online - link to read the book on full screen. Our eReader also allows you to upload and read Pdf, Txt, ePub and fb2 books. In the Mini eReder on the page below you can quickly view all pages of the book - Read Book Re-Design of the Transmission System of the Edison Electric Company of Southern California
What reading level is Re-Design of the Transmission System of the Edison Electric Company of Southern California book?
To quickly assess the difficulty of the text, read a short excerpt:

Smaller 9 25 Cycles* 60 Cycles* charging current • Induction motors have "better power factor.
Mixed load can be han- dled better.
25 cycles was selected as the best frequency for this case. It was also decided to use rotary coinrertors for getting 600 volt, direct current for railway purposes f and synchronous motor-generator sets for carrying the lighting load. 62^2 cycles was selected instead of 60 for the lighting circuits "because of the greater varie- ty of possible motor-generator speeds
.... With 25 to 60 cycle motor generator sets the only possible speeds are the sub-multiples of 300 while, if 62^2 cycles is used the available speeds are the sub -multiples of 750.
Standard 60 cycle apparatus can be used on the 62^2 cy- cle circuits since, at the slightly higher frequency the core loss and magnetizing current of transformers, etc. will be less, and the increase in frequency is not enough to interfere with such small motors as might be operated from the lighting circuits.
Before considering the question of voltage it 10 will be necessary to decide upon the scheme of trans- former connections to be used, since the cost of trans- formers depends upon their voltage, which in turn de- pends upon whether star or delta connection of the high- tension windings is to he used* The scheme decided up- on was star connection on the high-tension side and del- ta on the low, with the high-tension neutral grounded* It has many advantages over other combinations of star and delta connections.


What to read after Re-Design of the Transmission System of the Edison Electric Company of Southern California?
You can find similar books in the "Read Also" column, or choose other free books by Frank K Brainard to read online
MoreLess

Read book Re-Design of the Transmission System of the Edison Electric Company of Southern California for free

You can download books for free in various formats, such as epub, pdf, azw, mobi, txt and others on book networks site. Additionally, the entire text is available for online reading through our e-reader. Our site is not responsible for the performance of third-party products (sites).
Ads Skip 5 sec Skip
+Write review

User Reviews:

Write Review:

Guest

Guest